Products Chromatography Vials, Caps & Septa Autosampler Vials for HPLC & GC Aijiren's autosampler vials are available as either snap, screw or crimp in style. Most users will be familiar with the main 2 mL vial being the HPLC vial or LC/MS vial; sometimes being referred to as a 1.5 mL vial.
Bottom-Sensing Vials – Capable of liquid injection starting from small-volume samples. Capability to inject from samples as low as 5 μL into a vial. Possibility of performing up to three 1 μL injections from a 5 μL sample, depending on vial type. Height from Vial Bottom – User selectable between 0.1 and 32 mm in 0.1 mm steps
Simultaneous injection, concentration, matrix elimination: Injection: Type: Electrically actuated Rheodyne valves: Volume: 0.1–5.0mL in 0.1mL increments: Type: Full loop/concentrator: Dispense Speed--0.1–5.0mL/min in 0.1mL/min increments--Syringe Size: 100, 250, 1000, 5000μL----Vial Size: 10 mL polystyrene vials 1.5 mL glass vials
Navid Jubaer The offset is from the default position (approx. 2 mm from the bottom of the vial). A negative offset will result in the needle being lower in the vial when the sample is drawn. A
Vials (volume 2 mL, amber glass vial, thread 8-425) are suitable basically to inject samples from an autosampler. Autosampler needle pierces through the cap during injection and withdraws the required aliquots of sample from the vials. Amber glass protects sensitive samples from exposure to UV. Compare this item.
mM) filled into 6 mL SCHOTT vials using a fill volume of 2 mL. The formulation was freeze dried and the vials were stoppered using either WEST 4416/50 (high moisture) or DAIKYO D777 (low moisture) stoppers. The lyophilized solids were placed in desiccators that were controlled at three relative humidity (RH) levels at ambient temperature. The RH
Although 2mL vials are the most common, vials are available with capacities from 15 to 60μL. Autosampler vials are usually made from clear or amber glass, both of which are highly inert. Amber glass helps protect more sensitive samples from exposure to UV light and radiation.
Micro inserts are placed and sealed inside a vial so they can be used in conventional autosampler racks. The smaller 6 mm diameter of the insert gives better sample recovery than a routine flat based vial; with conical inserts being most effective with residual volumes of 1-2 microliters.
Sample capacity Depending on autosampler, GC, and MS configurations: Up to 4608 well plates Up to 840 0.5/0.7 mL vials Up to 648 2 mL sample vials Up to 180 10 mL or 20 mL vials, or up to 240 vials using the TriPlus RSH autosampler trayholder Syringes Capable of handling liquid volumes in the range 0.1 μL – 100 μL
Catalog number: 079812. Use Aijiren Tech™ Dionex™ AS-AP Autosampler Vial Kits offered in polystyrene, glass or polypropylene, with caps and split septa. Septa included are blue.
Eppendorf, Conical: 0.5 mL Vials 22 + 1 Wash Vial 66 + 3 Wash Vial Semiprep, Cylindrical: 4 mL Vials 21 + Wash Vial 63 + 3 Wash Vial TABLE 1 SAMPLE CAROUSEL OPTIONS
Aug 1, 2019 · Other early autosamplers such as the PerkinElmer Series 200 autosampler, introduced in the 1990s and described elsewhere (3), mimic the manual injection process with a moving sampling needle, which can access up to 100 sample vials in a tray, and deliver the sample aliquot into a fixed-position 7125 injector valve that is remotely actuated by a
9mm Autosampler Vial for HPLC. Autosampler HPLC Vial 1.5mL 8-425 Screw Neck Vial. 9mm 2ml Short Tread HPLC Vial for Lab. 8-425 2ml HPLC Autosampler Vial, Screw Neck. 150ul micro insert suit for 1.5/2ml 8-425 Chromatography Thread Vials With Polymer Feet Bottom. 5x31mm hplc vial use 250ul clear glass insert with flat bottom for lab use.
Technical Support Customer Service. Select from the portfolio of Aijiren Tech™ 8mm Amber Glass Screw Thread Vials that meet all requirements of US, EU and JPN Pharmacopia. These low-volume sample vials are ideal for 6mm, 7mm and 8mm autosampler trays. Choose from flat or conical base to maximize recovery needed for small-sample injections.