Zhejiang Aijiren Technology, Inc. is a global supplier of life-science, chemistry, laboratory consumables, etc. Our major products are high performance Autosampler Vials, Headspace Vials,Reagent Bottle,Syringe Filter,Sample Storage Vial,COD Test Tube,EPA Vials etc. Zhejiang Aijiren Technology, Inc. have been supplying to more than 70 countries, covers more than 2000 customers all over the world.
Sample stands ROTILABO ® for ND8 to ND11 autosampler vials Art. No. TY96.1 €85.50 / 1 unit(s)
10 hours ago · Autosampler vials are broadly used for performing analysis procedures in chromatography. These are essential commercial vials used within autosamplers so they must adhere strictly to specific dimensions. Autosampler vials are manufactured in a way that are compatible with all kind of autosampler systems. Manufacturing procedures for autosampler vials are highly assured for quality and
Feb 08, 2022 · 3.6.2 Stability in the autosampler. Glu(-HETE) and His(-HETE) derived from chicken serum references were stable over the entire test period of 24 h at 15°C not showing any trend of degradation (RSD of peak areas ≤9%), thus making these markers well suited even if larger sample sets are to be analyzed (data not shown). 3.6.3 Linear range
Sample capacity Depending on autosampler, GC, and MS configurations: Up to 4608 well plates Up to 840 0.5/0.7 mL vials Up to 648 2 mL sample vials Up to 180 10 mL or 20 mL vials, or up to 240 vials using the TriPlus RSH autosampler trayholder Syringes Capable of handling liquid volumes in the range 0.1 μL – 100 μL
HTR compact is the ideal choice for first-level rheology automation and offers high-throughput operation with 36 samples in two trays and 18 cups each. Add vials during operation with the sample drawer, while the rheometer and sample stage operate in parallel.
Aijiren sample vials design is characterized by universal ease of use, especially the use of automated sample introduction systems, so this type of vial is also called an autosampler vial. And this sample vial is extremely compatible. The 1.5ml sample vial we usually say is the 2ml volume sample vial.
The robotic vial processing operation allows sample analysis in a straightforward and simple way. Sample vials are transported into the heated six position incubator for preconditioning. After reaching the equilibration, a heated gas-tight syringe is moved over the incubator and the headspace sample is withdrawn.
The sample tray offers temperature control down to 4°C. The fast needle movements result in unsurpassed speeds of less than 30s for a full cycle. These features make the AS 110 a perfect fit for high throughput routine analysis. The autosampler is available with a standard or UHPLC 6 port or 10 port valve (6-PV or 10-PV).
Sample Vials. It is recommended that you submit the samples in autosampler vials with a screw top (PTFE septum). This is especially true if you have volatile solvents in your sample! Snap top vials can also be used for samples contained in less volatile samples such as water!
Eppendorf, Conical: 0.5 mL Vials 22 + 1 Wash Vial 66 + 3 Wash Vial Semiprep, Cylindrical: 4 mL Vials 21 + Wash Vial 63 + 3 Wash Vial TABLE 1 SAMPLE CAROUSEL OPTIONS
Jan 17, 2022 · Meanwhile, the autosampler moves the rack, injects the probe into a sample vial and begins uptake of the sample. Sample flows in through the bottom of the ultrafiltration membrane housing, is filtered, exits the top, and is sent directly to the cations sample loop, the anions sample loop and then to the waste container on the back of the
vials and closures from microsampling to headspace to match popular application requirements. Vial choices include: Crimp Top, Snap Top, and Screw top vials with a selection of closures. Refer to the Autosampler Compatibility Table on pages 10-11 to determine which vials, closures and inserts will work on your specific autosampler unit.
Sample Preparation & Autosampler Vials for ESI-MS. Use appropriate solvents for the ESI-MS system. a. Appropriate solvents include: b. If your compound is not sufficiently soluble in one of the above, you can first dissolve it in DMSO, but you must dilute the DMSO to 0.1%. or less in the sample you run.